4 x Temperature IN

4-channel analogue input
Temperature acquisition

µCAN.4.ti-BOX

Home 9 Portfolio 9 I/O Modules 9 BOX 9 µCAN.4.ti-BOX

The µCAN.4.ti-BOX features 4 inputs for measuring temperature sensors such as RTD and thermocouples with 400 Hz total sampling rate. The CAN interface supports the protocols CANopen and J1939.

µCAN.4.ti-BOX: Temperature acquisition 4-channel

Features

  • Temperature Thermo type J, K, N, R, T
  • Temperature Pt100, Pt200 (2- / 4-core)
  • Temperature Pt500, Pt1000 (2- / 4-core)
  • Accuracy +/- 0.1 K
  • Resolution 16-bit (0.1 °C)
  • Sampling rate 10 ms / 100 Hz
  • Galvanically isolated fieldbus
  • Cold junction compensation on module
  • Signal type freely configurable
  • Protected against mechanical stress
  • Fieldbus CAN
  • Protocol CANopen / CAN RAW

Further designs

Ordering information

Item no.
12.43.005
90.01.114
Description
µCAN.4.ti-BOX

4-channel temperature acquisition module with CANopen, signal acquisition thermocouple type J,K,L,R,T, Pt100, Pt500 and Pt1000, 16-bit resolution, designed for metric cable connectors. Signal wiring via screw terminals.

Metric cable connection kit for 4-channel fieldmodules

Downloads

Datasheet µCAN.4.ti-BOX
4-channel analogue input temperature
PDF [723 KB]

Manual µCAN.4.ti-BOX
4-channel analogue input temperature
PDF [1 .0 MB]

CANopen EDS file
mcan4ti_box_v4r08.eds
EDS [23 KB]

Order a sample module

Get a

sample module!

Any questions?

+49 2241 – 25 65 9 – 0

Write an email or call us.