16 x Temperature IN

CANopen 19″-slide-in module
or temperature measurement

µLAB.16.ti-19″ / Thermocouple

Home 9 Portfolio 9 I/O Modules 9 19″-System 9 µLAB.16.ti-19″ / Thermocouple

Equipped with CAN or CANopen interfaces and a 19″ slide-in casing, the MicroControl µLAB is particulary suitable for measuring electric, thermal and mechanic signals in engine or components testing facilities. The signal wires are connected to the module by plug-in connectors in the front plate.

µLAB.16.ai-19″: Data acquisition in a 19″ slide-in module

Features

  • Temperature thermo type K
  • Accuracy +/- 0.1 K
  • Resolution 16-bit (0.1 °C)
  • Sampling rate 10 ms / 100 Hz
  • galvanically isolated fieldbus
  • Sensor error detection
  • Equipped with cold-junction compensation
  • Operating temperatures -40…+85 °C
  • Supply voltage 9…36 V DC
  • Connection via thermo plug-in
  • Fieldbus CAN
  • Protocol CANopen / CAN RAW

Further designs

Ordering information

Item no.
41.01.104
Description
µLAB.16.ti-19" / thermo type K

19" Slide-in for temperature acquition of 16 sensors thermo type k (green) with CANopen, signal acquisition via thermo plug-in connector, 24V DC supply via Combicon 5-pole connector, CAN connection via 2 x M12 Binder socket/plug, 19" Slide-in (1.094.171.3.000001) incl. front plate without handles, fuse T2.5A for M12 socket/plug, factory calibration