;=============================================================================; ; ; ; File: mcan8pwm_box_v2r00.eds ; ; Description: CANopen Electronic Data Sheet (EDS) for the analog ; ; inout module µCAN.8.pwm-BOX ; ; ; ; Copyright (C) MicroControl GmbH & Co. KG ; ; Lindlaustr. 2c ; ; 53842 Troisdorf ; ; Germany ; ; Tel: +49-2241-25659-0 ; ; Fax: +49-2241-25659-11 ; ; ; ;=============================================================================; ;------------------------------------------------------------------------------ ; SVN $Date: 2006-08-02 12:05:04 +0200 (Mi, 02 Aug 2006) $ ; SVN $Rev: 168 $ --- $Author: koppe $ ;------------------------------------------------------------------------------ [FileInfo] FileName=mcan8pwm_box_v2r00.eds FileVersion=1 FileRevision=0 EDSVersion=4.0 Description=EDS for µCAN.8.pwm-BOX CreationTime=14:00PM CreationDate=03-24-2006 CreatedBy=J. Tiderko ModificationTime=16:15PM ModificationDate=06-30-2006 ModifiedBy=J. Tiderko [DeviceInfo] VendorName=MicroControl GmbH & Co. KG VendorNumber=14 ProductName=µCAN.8.pwm-BOX ProductNumber=1287002 RevisionNumber=2 OrderCode=12.87.002 LSS_Supported=1 BaudRate_10=0 BaudRate_20=1 BaudRate_50=1 BaudRate_125=1 BaudRate_250=1 BaudRate_500=1 BaudRate_800=1 BaudRate_1000=1 SimpleBootUpMaster=0 SimpleBootUpSlave=1 Granularity=0 GroupMessaging=0 DynamicChannelsSupported=0 NrOfRXPDO=2 NrOfTXPDO=0 ;-----------------------------------------------------------------------------; ; Mandatory objects ; ;-----------------------------------------------------------------------------; [MandatoryObjects] SupportedObjects=3 1=0x1000 2=0x1001 3=0x1018 [1000] ParameterName=DeviceType ObjectType=0x7 DataType=0x7 AccessType=ro DefaultValue=0x00000000 PDOMapping=0 [1001] ParameterName=ErrorRegister ObjectType=0x7 DataType=0x5 LowLimit=0x0 HighLimit=0xff AccessType=ro DefaultValue=0x0 PDOMapping=0 [1018] SubNumber=5 ParameterName=Identity Object ObjectType=0x9 [1018sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x5 LowLimit=0x01 HighLimit=0x04 AccessType=ro DefaultValue=4 PDOMapping=0 [1018sub1] ParameterName=Vendor ID ObjectType=0x7 DataType=0x7 AccessType=ro DefaultValue=0x0000000e PDOMapping=0 [1018sub2] ParameterName=Product code ObjectType=0x7 DataType=0x7 AccessType=ro DefaultValue=0x0013A35A PDOMapping=0 [1018sub3] ParameterName=Revision number ObjectType=0x7 DataType=0x7 AccessType=ro PDOMapping=0 [1018sub4] ParameterName=Serial number ObjectType=0x7 DataType=0x7 AccessType=ro PDOMapping=0 ;-----------------------------------------------------------------------------; ; Optional objects ; ;-----------------------------------------------------------------------------; [OptionalObjects] SupportedObjects=19 1=0x1002 2=0x1003 3=0x1005 4=0x1008 5=0x1009 6=0x100A 7=0x100C 8=0x100D 9=0x1010 10=0x1011 11=0x1014 12=0x1016 13=0x1017 14=0x1029 15=0x1400 16=0x1401 17=0x1600 18=0x1601 19=0x1F80 ;--- 1002h: Manufacturer status ------------------------------------- [1002] ParameterName=Manufacturer status ObjectType=0x7 DataType=0x7 LowLimit=0x0 HighLimit=0xffffffff AccessType=ro DefaultValue=0x0 PDOMapping=0 ;--- 1003h: Pre-defined error field --------------------------------- [1003] SubNumber=2 ParameterName=Pre-defined error field ObjectType=0x08 [1003sub0] ParameterName=Number of errors ObjectType=0x07 DataType=0x05 LowLimit=0x01 HighLimit=0x04 AccessType=ro DefaultValue=0x00 PDOMapping=0 [1003sub1] ParameterName=Standard error field 1 ObjectType=0x07 DataType=0x07 LowLimit=0x00000000 HighLimit=0xffffffff AccessType=ro DefaultValue=0x00000000 PDOMapping=0 ;--- 1005h: COB-ID SYNC message ------------------------------------- [1005] ParameterName=COB-ID SYNC message ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x80 PDOMapping=0 ;--- 1008h: Manufacturer device name -------------------------------- [1008] ParameterName=Manufacturer device name ObjectType=0x07 DataType=0x09 AccessType=const DefaultValue=mCAN.8.pwm-BOX PDOMapping=0 ;--- 1009h: Manufacturer Hardware Version --------------------------- [1009] ParameterName=Manufacturer hardware version ObjectType=0x07 DataType=0x09 AccessType=const DefaultValue=2.10-HS PDOMapping=0 ;--- 100Ah: Manufacturer Software Version --------------------------- [100A] ParameterName=Manufacturer software version ObjectType=0x07 DataType=0x09 AccessType=const DefaultValue=2.00 PDOMapping=0 ;--- 100Ch: Guard time ---------------------------------------------- [100C] ParameterName=Guard time ObjectType=0x07 DataType=0x06 LowLimit=0x0000 HighLimit=0xffff AccessType=rw DefaultValue=0x0000 PDOMapping=0 ;--- 100Ch: Life time factor ---------------------------------------- [100d] ParameterName=Life time factor ObjectType=0x07 DataType=0x05 LowLimit=0x00 HighLimit=0xff AccessType=rw DefaultValue=0x00 PDOMapping=0 ;--- 1010h: Store parameters ---------------------------------------- [1010] SubNumber=5 ParameterName=Store parameters ObjectType=0x08 [1010sub0] ParameterName=Number of entries ObjectType=0x07 DataType=0x05 LowLimit=0x04 HighLimit=0x04 AccessType=ro DefaultValue=0x04 PDOMapping=0 [1010sub1] ParameterName=Save all parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 [1010sub2] ParameterName=Save communication parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 [1010sub3] ParameterName=Save application parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 [1010sub4] ParameterName=Save manufacturer parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 ;--- 1011h: Restore default parameters ------------------------------ [1011] SubNumber=5 ParameterName=Restore default parameters ObjectType=0x08 [1011sub0] ParameterName=Number of entries ObjectType=0x07 DataType=0x05 LowLimit=0x01 HighLimit=0x04 AccessType=ro DefaultValue=0x4 PDOMapping=0 [1011sub1] ParameterName=Restore all default parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 [1011sub2] ParameterName=Restore communication default parameters ObjectType=0x7 DataType=0x7 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 [1011sub3] ParameterName=Restore application default parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 [1011sub4] ParameterName=Restore manufacturer default parameters ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000001 PDOMapping=0 ;--- 1014h: COB-ID emergency message -------------------------------- [1014] ParameterName=COB-ID emergency message ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=$NODEID+0x80 PDOMapping=0 ;--- 1016h: Consumer heartbeat time --------------------------------- [1016] SubNumber=3 ParameterName=Consumer heartbeat time ObjectType=0x08 [1016sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x5 LowLimit=0x01 HighLimit=0x02 AccessType=ro DefaultValue=0x02 PDOMapping=0 [1016sub1] ParameterName=Consumer heartbeat time 1 ObjectType=0x07 DataType=0x07 LowLimit=0x00000000 HighLimit=0x007FFFFF AccessType=rw DefaultValue=0x00000000 PDOMapping=0 [1016sub2] ParameterName=Consumer heartbeat time 2 ObjectType=0x7 DataType=0x7 LowLimit=0x00000000 HighLimit=0x007FFFFF AccessType=rw DefaultValue=0x0 PDOMapping=0 ;--- 1017h: Producer heartbeat time --------------------------------- [1017] ParameterName=Producer heartbeat time ObjectType=0x07 DataType=0x06 LowLimit=0x0000 HighLimit=0xffff AccessType=rw DefaultValue=0x0000 PDOMapping=0 ;--- 1029h: Error behaviour ----------------------------------------- [1029] SubNumber=2 ParameterName=Error behaviour ObjectType=0x08 [1029sub0] ParameterName=Number of entries ObjectType=0x07 DataType=0x05 LowLimit=0x01 HighLimit=0x01 AccessType=ro DefaultValue=0x01 PDOMapping=0 [1029sub1] ParameterName=Communication error ObjectType=0x07 DataType=0x05 LowLimit=0x00 HighLimit=0x02 AccessType=rw DefaultValue=0x00 PDOMapping=0 ;--- 1400h: RPDO 1 communication parameter -------------------------- [1400] SubNumber=3 ParameterName=RPDO 1 communication parameter ObjectType=0x09 [1400sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x5 AccessType=ro DefaultValue=0x2 PDOMapping=0 [1400sub1] ParameterName=COB-ID used by PDO ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=$NODEID+0x40000200 PDOMapping=0 [1400sub2] ParameterName=Transmission type ObjectType=0x07 DataType=0x05 AccessType=rw DefaultValue=0xff PDOMapping=0 ;--- 1401h: RPDO 2 communication parameter -------------------------- [1401] SubNumber=3 ParameterName=RPDO 2 communication parameter ObjectType=0x09 [1401sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x5 AccessType=ro DefaultValue=0x2 PDOMapping=0 [1401sub1] ParameterName=COB-ID used by PDO ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=$NODEID+0x40000300 PDOMapping=0 [1401sub2] ParameterName=Transmission type ObjectType=0x07 DataType=0x05 AccessType=rw DefaultValue=0xff PDOMapping=0 ;--- 1600h: RPDO 1 mapping parameter -------------------------------- [1600] SubNumber=5 ParameterName=RPDO 1 mapping parameter ObjectType=0x09 [1600sub0] ParameterName=Number of mapped objects ObjectType=0x07 DataType=0x05 AccessType=ro DefaultValue=0x04 PDOMapping=0 [1600sub1] ParameterName=Mapping for object 1 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100110 PDOMapping=0 [1600sub2] ParameterName=Mapping for object 2 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100210 PDOMapping=0 [1600sub3] ParameterName=Mapping for object 3 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100310 PDOMapping=0 [1600sub4] ParameterName=Mapping for object 4 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100410 PDOMapping=0 ;--- 1601h: RPDO 2 mapping parameter -------------------------------- [1601] SubNumber=5 ParameterName=RPDO 2 mapping parameter ObjectType=0x09 [1601sub0] ParameterName=Number of mapped objects ObjectType=0x07 DataType=0x05 AccessType=ro DefaultValue=0x04 PDOMapping=0 [1601sub1] ParameterName=Mapping for object 5 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100510 PDOMapping=0 [1601sub2] ParameterName=Mapping for object 6 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100610 PDOMapping=0 [1601sub3] ParameterName=Mapping for object 7 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100710 PDOMapping=0 [1601sub4] ParameterName=Mapping for object 8 ObjectType=0x07 DataType=0x07 AccessType=ro DefaultValue=0x52100810 PDOMapping=0 ;--- 1F80h: NMT startup --------------------------------------------- [1F80] ParameterName=NMT startup ObjectType=0x07 DataType=0x07 AccessType=rw DefaultValue=0x00000000 PDOMapping=0 ;-----------------------------------------------------------------------------; ; Manufacturer objects ; ;-----------------------------------------------------------------------------; [ManufacturerObjects] SupportedObjects=3 1=0x5020 2=0x5200 3=0x5210 ;--- 5020h: Device supply voltage ----------------------------------- [5020] ParameterName=Device supply voltage ObjectType=0x07 DataType=0x03 LowLimit=0x00 HighLimit=0xffff AccessType=ro DefaultValue=0x00 PDOMapping=0 ;--- 5200h: PWM-Frequency ------------------------------------------- [5200] SubNumber=9 ParameterName=PWM Frequency ObjectType=0x08 [5200sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x5 AccessType=ro DefaultValue=0x8 PDOMapping=0 [5200sub1] ParameterName=PWM Channel 1 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub2] ParameterName=PWM Channel 2 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub3] ParameterName=PWM Channel 3 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub4] ParameterName=PWM Channel 4 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub5] ParameterName=PWM Channel 5 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub6] ParameterName=PWM Channel 6 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub7] ParameterName=PWM Channel 7 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 [5200sub8] ParameterName=PWM Channel 8 ObjectType=0x07 DataType=0x06 LowLimit=0x19 HighLimit=0x1388 AccessType=rw DefaultValue=0x0028 PDOMapping=0 ;--- 5210h: PWM-Duty Cycle ------------------------------------------ [5210] SubNumber=9 ParameterName=PWM Duty Cycle ObjectType=0x08 [5210sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x5 AccessType=ro DefaultValue=0x8 PDOMapping=0 [5210sub1] ParameterName=PWM Channel 1 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub2] ParameterName=PWM Channel 2 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub3] ParameterName=PWM Channel 3 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub4] ParameterName=PWM Channel 4 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub5] ParameterName=PWM Channel 5 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub6] ParameterName=PWM Channel 6 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub7] ParameterName=PWM Channel 7 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [5210sub8] ParameterName=PWM Channel 8 ObjectType=0x07 DataType=0x06 LowLimit=0x00 HighLimit=0x03E8 AccessType=rww DefaultValue=0x0000 PDOMapping=1 [DummyUsage] Dummy0001=0 Dummy0002=0 Dummy0003=0 Dummy0004=0 Dummy0005=0 Dummy0006=0 Dummy0007=0 [Comments] Lines=0